SAP 305762
Capacity 260 L
Height 2010 m
Energy class A+
Maximum
operational temperature
75 °C
Maximum working pressure 8 bar
Diameter 630 mm
Declared load profile XL
Electric heating element power 1.5 kW
Min. ÷ max temperature heat pump air intake (90% R.H.) -10 ÷ 43 °C
Frequency 50 Hz
Annual electricity consumption in kWh under average climate conditions 1136 kWh
Power supply 1/N/220-240 V
Compressor Rotary
Min. ÷ max temperature installation site -4 ÷ 40 °C
Compressor protection Thermal circuit breaker with automatic reset
Maximum current in HP 3.1 + 6.5 (e-heater) = 9.6 A
Required overload protections 16A T fuse/ 16 A automatic switch characteristic C (to be expected during installation on power supply systems)
Fan Centrifugal
HP Maximum settable temperature 65 °C
Internal protection Single safety thermostat with manual reset on a resistive element
Nominal air capacity 360 m³/h
Motor protection Internal thermal circuit breaker with automatic reset
Condenser Wrapped externally not in contact with water
Transport weight 110 kg
Automatic anti-Legionnella disinfection cycle YES
Minimum height of the premise 2055 mm
CoP (DHW) 3.6
Heat Pump Thermal Power yield (P rated) 1.43 kW
Degree of Protection IPX4
Refrigerant R513a
Refrigerant charge 1100 g
CO2 equivalent 0.693
Average heat pump consumption [Condition EN16147:2017 A7/W55] 0.400 kW